What was found
APU FAULT LIGHT ILLUMINATED UPON ENGAGING START SWITCH AFTER LANDING. GROUNDED - YES. REMOVED AND REPLACED INLET TEMPERATURE SENSOR OPS CHECK GOOD. APU START SUCCESSFUL NO FAULT LIGHT ILLUMINATED. REF B737-800 AMM 49-61-31.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
APU FAULT LIGHT ILLUMINATED UPON ENGAGING START SWITCH AFTER LANDING. GROUNDED - YES. REMOVED AND REPLACED INLET TEMPERATURE SENSOR OPS CHECK GOOD. APU START SUCCESSFUL NO FAULT LIGHT ILLUMINATED. REF B737-800 AMM 49-61-31.