What was found
#2 FQIS FAILS SYSTEM TEST. THE FOLLOWING PROBES ARE OUT OF ACCEPTABLE CAPACITANCE VALUES PER AMM TASK 28-41-21-710-801: COMP., TU4, TU5, TU6, TU7, AND TU8. GROUNDED - YES. REMOVED AND REPLACED COMP PROBE, TU4 AND TU6 PROBES REF B737-800 AMM 28-41-21/401. REPLACED PROBE TU5 PER AMM 28-41-21. REMOVED AND REPLACED TU7 AND TU8 REF AMM 28-41-21/401. ACCOMPLISHED FUEL QUANTITY IND SYS TEST, OPS NML REF AMM 28-41-00-730-801.