What was found
FWD PIT DOOR CUTOUT LOWER SILL WEB IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED SILLWEB IAW 737-900 SRM 51-40-02-0G-0W-1" O-.045" R-.034" L-2" D-.011".
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD PIT DOOR CUTOUT LOWER SILL WEB IS CORRODED. GROUNDED - YES. REMOVED AND REPLACED SILLWEB IAW 737-900 SRM 51-40-02-0G-0W-1" O-.045" R-.034" L-2" D-.011".