What was found
RIGHT PACK LIGHT ILLUMINATED ON MASTER CAUTION RECALL, LIGHT EXTINGUISHES WHEN MASTER CAUTION SYSTEM IS RESET. GROUNDED - YES. DURING BITE RH TEMP CONTROL VALVE FAULTED. REMOVED AND REPLACED RH TEMPERATURE CONTROL VALVE IAW B737-800 AMM 21-51-10-000-801 AND AMM 21-51-10-400-801, ETOPS GROUND VERIFICATION CHECK GOOD IAW AMM 21-61-00-700-806-002.