What was found
FLOOR SUPPORT AT STA 767 RBL 13 IS CORRODED. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW B737-900 SRM 53-00-53-1A-2 REPAIRED SUPPORT IAW B737-90ER SRM 53-00-53-2R-3W=1 O=.070 R= <50% L=3 D= >50%.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT AT STA 767 RBL 13 IS CORRODED. GROUNDED - YES. REMOVED CORROSION AND CHECKED LIMITS FOUND TO BE OUT OF LIMITS IAW B737-900 SRM 53-00-53-1A-2 REPAIRED SUPPORT IAW B737-90ER SRM 53-00-53-2R-3W=1 O=.070 R= <50% L=3 D= >50%.