Service difficulty report · Eec · Boeing 737990ER

Difficulty date
May 28, 2022
Submitted
May 31, 2022
Operation
Air carrier
Aircraft
N440AS
Make and model
Boeing 737990ER
Aircraft serial
41705
Aircraft time
32,186 hours, 10,225 cycles
Engine
Cfmint CFM567B27E
Part
Eec
Part number
2042M67P02
Part serial
FFFB0444
Condition
Faulty
Location
#2 Engine
Part time
29,482 hours, 10,316 cycles
Stage of operation
IN
How discovered
O
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ENG #2 SHORT TIME FAULT, 73-20322 - THE HMU FMV CONTROL CURRENT IS OUT OF RANGE, 75-20372 - THE HMU VSV CONTROL CURRENT IS OUT OF RANGE, 75-20422 - THE HMV VBV CONTROL CURRENT IS OUT OF RANGE, 78-21532 THE T/R LEVEL INTLK VOLTAGE INPUT TO THE EEC IS OUT OF RANGE, 73-20342 THE FMV POSITION SIGNAL IS OUT OF RANGE. DEFER PER T/C 78273000. GROUNDED - YES. FOUND EEC TO BE FAILING AND LOGGING MULTIPLE FAULTS. REMOVED & REPLACED #2 EEC. OP CK NORMAL. EEC BITE NORMAL BOTH PRE & POST ENGINE RUN. ACTUATORS TEST NORMAL. REF B737-900 AMM 73-21-60-00-801-F00 & 73-21-60-400-801-F00.