What was found
FT PIT R/H TRANSITION PANEL STA 727H+15 HAS PUNCTURE. GROUNDED - YES. EVALUATED AFT PIT R/H TRANSITION PANEL STA 727H+15, PUNCTURE .400" IN DIAMETER , OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-2 PAR 4-A.(4). REMOVED AND FAB NEW REPAIR PART AND DOUBLER AND INSTALLED NEW AFT PIT R/H TRANSITION PANEL STA 727H+15 USING MATERIAL BAC 1496-377 7075-T62 PO: 1014538.1IAW B737-800 SRM 53-00-53-2R-5 REPAIR 5.