What was found
ENG 1 REVERSER UNLOCKED IN FLIGHT GROUNDED - YES. VERIFIED ACCOMPLISHMENT OF DEACTIVATION OF BOTH THE HYD INHIBITION AND MECHANICAL INHIBITION OF #1 REVERSER MEL ON L/P 60461158. BOTH CURRENTLY DEACTIVATED AS PER THE MEL. ASA 16330 INTERMITTANT 2424-TR TLS UNLOCK FAULT. OCCURS ON A AND B CHANNELS DURING ICV TEST. SWAPPED CONNECTORS DURING TESTING AND FAULTS ON BOTH A AND B CHANNELS WITH SENSORS CONNECTED TO OPPOSITE HARNESSES REF TSM TASK 78-37-00-810-839-A AT STEP 4 "FAULT ISOLATION" B.(2).(B).1, TIE-IN TO DAYSHIFT. ASA 98500 06/16/2022 SECURED EXTERNAL PWR. ACCOMP. CH.A AND CH. B TLS WIRING CHECKES, ALL WITHIN LIMITS UNDER 2.0 OHMS. GVI OF CONNECTORS OK REF TSM 78-37-00-810-83-A AND 840-A. E OIE 60950 06/16/2022. INITIATED MIG 2C 40-0037503. REMOVED AND REPLACED #1 ENG ICU REF MM 78-31-51. LK AND OPS CKS GOOD. JGENNETT 53180 06/16/2022 MIG 2C 40-0037503 CLOSED. T/R REACTIVATED REF MM 78-30-00