What was found
AFT CARGO L/H AFT TRANSITION PANEL IS CORRODED. GROUNDED - YES. PERFORMED SURFACE BLEND REMOVED CORROSION, STA 727K+6 - 727L+6 FOUND TO BE OUT OF LIMITS REPAIRED SECTION, ALL OTHER AREAS FOUND TO BE WITHIN LIMITS, RESTORED FINISH IAW B737-900 SRM 53-00-53-2R-5 SRM 53-00-53-1A-2W 6" O .040 R .039 L 6' D .001.