What was found
PER ASA T/C 78273000 FOUND #1 ENG SHORT TIME FAULT 73-10341, THE FMV POSITION SIGNAL IS OUT OF RANGE. GROUNDED - YES. REMOVED AND REPLACED HMU AND FUEL PUMP AS A PACKAGE REF ASA TC/ N8473002, N8473003, N28473000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PER ASA T/C 78273000 FOUND #1 ENG SHORT TIME FAULT 73-10341, THE FMV POSITION SIGNAL IS OUT OF RANGE. GROUNDED - YES. REMOVED AND REPLACED HMU AND FUEL PUMP AS A PACKAGE REF ASA TC/ N8473002, N8473003, N28473000.