What was found
CREW REPORTS FMC DISAGREE MESSAGE. GROUNDED - YES. BOTH FMCS SET ON-GROUND RIGHT CDU FAILURE. GENERATING FAULTS ARE CDU-R ARINC-INTERMITTENT-RATE, AND CDU-R INTERMITTENT-FAILURE. RESET CDU RIGHT POWER. FMC DISAGREE MESSAGES EXTINGUISH. ACCOMPLISHED RIGHT CDU INSTALLATION TESTS PER B737-9 AMM 34-61-01 AND SOFTWARE CONFIGURATION TESTS PER AMM 34-61-00 AND B737-9 AIPC 34-61-01-10 W/ NO DEFECTS INDICATED. ETOPS GROUND VERIFICATION SUCCESSFUL.