What was found
FWD PIT R/H TRANSITION PANEL FROM STA 500H TO 500I HAS CORROSION. GROUNDED - YES. REMOVED DAMAGE FROM FWD PIT R/H TRANSITION PANEL FROM STA 500H TO 500I IAW B737-800 SRM 53-00-53-1A-2 STEP 4.A ORIGINAL THICKNESS IS .040 IAW B737-800 SRM 53-30-53-0I-2 TABLE 2REMOVED .010REMAINING THICKNESS IS .030AND IS FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-00-53-1A-2 STEP 4.A.(1).(A) TOOL# T8224L DUE DATE 15/OCT/22REPAIRED FWD PIT TRANSITION PANEL FROM STA 500D+10 TO 500I USING MATERIAL BAC1496-444 IAW B737-800 SRM 53-00-53-2R-5.