What was found
FLOOR SUPPORT AT STA 259.5 HAS AREAS OF CORROSION ON UPPER FLANGE BETWEEN LBL-10 TO RBL-10. GROUNDED - YES. REPAIRED FLOOR SUPPORT AT STA 259.5 IAW ASA EA# 700-53EA-24860. THIS IS A CATEGORY B REPAIR WITH FIRST STAGE APPROVAL FOR STATIC STRENGTH AND WILL REQUIRE A NEW 8100-9 TO BE ISSUED FINDING COMPLIANCE WITH 14CFR26.43(D) PRIOR TO 9 NOV 2024.W=.850 O=.080 R=0.0 L=2.4 D=.080.