What was found
#1 FQIS FAILS SYSTEM TEST AT 404.7 PICO FARADS, REF AMM TASK 28-41-00-730-801. COMPENSATOR, TU1, TU2, TU3 , TU7 AND TU10 ARE OUT OF ACCEPTABLE LIMITS. GROUNDED - YES. REMOVED AND REPLACED PROBES - COMPENSATOR, TU1, TU2, TU3, TU7, AND TU10 REF B737-800 AMM 28-41-21/401. #1 FQIS SYSTEM TEST NOW GOOD AT 396.4/57.81 PICO FARADS. FOR INSPECTION REQUIREMENTS, POWER DEACTIVATION, & LEAK CHECKS REF TANK ENTRY TASK CARD 78528000-LINE.