What was found
MAIN CABIN OUTBD FLOORBEAM UPPER SURFACE HAS CORROSION IN 2EA PLACES AT FR68 JUST INBD OF GIRT BAR FITTING. GROUNDED - YES. ACCOMPLISHED CATEGORY "A" PERMANENT REPAIR AT MAIN CABIN R/H OUTBD DOOR SILL AT FR68 IAW SRM 53-41-14-80-A AND SRM 53-41-14-300-001 REV. 142 01 AUG 2022.