What was found
STA 947.5 HAS CORROSION AT I/B AND O/B LAV ATTACH POINTS. GROUNDED - YES. REPAIRED FLOOR BEAM STA 947.5 IAW 737-700 SRM 53-70-51-2R-5 REPAIR 5.W= 2" O= .180 R= 0.000 L= 67.5" D= .180.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
STA 947.5 HAS CORROSION AT I/B AND O/B LAV ATTACH POINTS. GROUNDED - YES. REPAIRED FLOOR BEAM STA 947.5 IAW 737-700 SRM 53-70-51-2R-5 REPAIR 5.W= 2" O= .180 R= 0.000 L= 67.5" D= .180.