What was found
AFT CABIN ZONE TEMP ON RECALL - CLEARS WHEN MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED RH AFT TRIM MODULATING VALVE REF B737-800 AMM 21-61-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AFT CABIN ZONE TEMP ON RECALL - CLEARS WHEN MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED RH AFT TRIM MODULATING VALVE REF B737-800 AMM 21-61-21.