Service difficulty report · Sensor · Boeing 737990ER

Difficulty date
January 9, 2023
Submitted
January 10, 2023
Operation
Air carrier
Aircraft
N413AS
Make and model
Boeing 737990ER
Aircraft serial
35205
Aircraft time
36,479 hours, 11,495 cycles
Engine
Cfmint CFM567B27E
Part
Sensor
Part number
1296663
Part serial
12721
Condition
Faulted
Location
Nr 2 Precooler
Part time
48,903 hours, 18,576 cycles
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

NUMBER 2 BLEED TRIP OFF ILLUMINATED AFTER TAKE OFF. FOLLOWED QRH GUIDANCE AND ATTEMPTED A TRIP RESET. BLEED TRIP OFF LIGHT EXTINGUISHED, BUT RE-ILLUMINATED AFTER A FEW SECOND. GROUNDED - YES. REMOVED AND REPLACED PRECOOLER CONTROL VALVE SENSOR & OVER TEMPERATURE SWITCH REF. B737-900 AMM 36-11-08, 36-12-03.