Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
January 14, 2023
Submitted
January 17, 2023
Operation
Air carrier
Aircraft
N532AS
Make and model
Boeing 737890
Aircraft serial
36346
Aircraft time
45,400 hours, 13,384 cycles
Part
Modulating Valve
Part number
3989083
Part serial
2915
Condition
Faulted
Location
Left Ecs Bay
Part time
15,113 hours, 4,349 cycles
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

"CONT CABIN" ZONE TEMP LIGHT ILLUMINATES ON RECALL IT EXTINGUISHES WITH MASTER CAUTION RESET. GROUNDED - YES. REMOVED AND REPLACED TEMPERATURE CONTROL VALVE IN REF TO B737-800 AMM 21-51-10.