What was found
FWD PIT, AFT BULKHEAD L/H LOWER SUPPORT IS CORRODED. GROUNDED - YES. EVAL'D FWD PIT, AFT BULKHEAD L/H LOWER SUPPORT, IS 100% MAT'LOSS OUT OF LIMITS IAW B737-800 SRM 53-30-08-1A-1, REMOVED OLD LOCATED AND DRILLED NEW AND INSTALLED NEW PN; 143A9488-23, PO:1047883.3 FWD IT AFT BULKHEAD L/H LOWER SUPPORT IAW B737-800 SRM 51-40-02 AND SRM 51-40-05.