What was found
"PACK" LIGHT LEFT. ILLUMINATES ONLY ON RECALL, EXTINGUISH MASTER RESET. GROUNDED - YES. (RESOLVED ON W/O: 1939921 TASKCARD: N/R-00002 ) REMOVED AND REPLACED L/H PACK TEMP CONTROL VALVE REF B737-800 AMM 21-61-21. BITE CHECK AND LEAK CHECK GOOD. THIS CLEARS MEL 21-32B FOR DEFECT NO. 60295533. PLACARDS REMOVED. SEAMC CARL NOTIFIED.