What was found
CONT ZONE TEMP CAUTION LIGHT ILLUMINATED DURING INITIAL CLIMB PERFORMED QRH LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. GROUNDED - YES. REMOVED AND REPLACED CONTROL ZONE TEMP MODULATING VALVE PER B737-800 AMM 21-61-21/401.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CONT ZONE TEMP CAUTION LIGHT ILLUMINATED DURING INITIAL CLIMB PERFORMED QRH LIGHT ILLUMINATED DURING MASTER CAUTION RECALL. GROUNDED - YES. REMOVED AND REPLACED CONTROL ZONE TEMP MODULATING VALVE PER B737-800 AMM 21-61-21/401.