Service difficulty report · Bleed Valve · Boeing 737890

Difficulty date
March 15, 2023
Submitted
March 17, 2023
Operation
Air carrier
Aircraft
N579AS
Make and model
Boeing 737890
Aircraft serial
35187
Aircraft time
57,731 hours, 16,952 cycles
Part
Bleed Valve
Part number
32145526
Part serial
7840
Condition
Failed
Location
#1 Engine
Part time
56,544 hours, 20,157 cycles
Stage of operation
NR
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DUCT PRESSURE DIFFERENTIAL DURING FLIGHT GREATER THAN 20 PSI. 5000FT R-40PSI L-5PSI, 10000FT R-45 L-7, 20000FT R-47 L-7, 30000FT R-47 L-8@ 340FL CABIN ALT 7200, DIFF 7.7. GROUNDED - YES. ACCOMPLISHED #1 ENGINE PNEUMATIC SYSTEM HEALTH CHECK REF. TC NG-36WC-0002-1. FOUND PRSOV BAD. REMOVED & REPLACED PRSOV REF. B737-800 AMM 36-11-04.