What was found
E&E ACCESS BAY: PUNCTURE ON LH SIDE OF E&E ACCESS DOOR FRAME ABOVE LATCH REVEIVER. GROUNDED - YES. REMOVED DAMAGED WEB PER B737-900 SRM 51-40-02LOCATED MAT ID AND FABBED WEB PER B737-900 SRM 51-40-05, DWG 141A8512 REV E AND GPM 05-00-85.APPLIED PROTECTIVE TREATMENT PER B737-900 SRM 51-70-01INSTALLED WEB PER B737-900 SRM 51-40-02, REF DWG 141A8512 AND GPM 05-00-85APPLIED CIC PER B737-900 SRM 51-20-01.