What was found
FWD PIT L/H TRANSITION PANEL AT STA 500H-500I IS CORRODED. GROUNDED - YES. REMOVED THE CORROSION FROM THE FWD PIT L/H TRANSITION PANEL AT STA 500H-500I PER B737-800 SRM 53-00-533-1A-2.2.D. ORIG THICKNESS IS .040" PER B737-800 SRM 53-30-53-0I-2 TABLE 2. REMOVED .020". REMAINING THICKNESS IS .020" AND IS FOUND TO BE OUT OF LIMITS PER B737-800 SRM 53-00-53-1A-2.4.A.(2). REMOVED. FAB'D LOCATED & DRILLED NEW USING BAC 1466-444 7075-T6. PO:1059596.1, APPLIED ALODINE, PRIMER, AND NUTPLATES, AND INSTALLED NEW TRANSITION PANEL 500G+10-500I AW B737-800 SRM 53-00-53-2R-5.