What was found
AFT PIT, LH TRANSITION PANEL IS CORRODED AT STA 727H+14-757. GROUNDED - YES. EVALUATED AFT CARGO L/H TRANSITION PANEL FROM FR STA 727H +14 TO FR STA 757 ORIGINAL MATERIAL THKS .040 PER BAC PROFILE DWG 1496-377 REMOVED .005 REMAINING .035 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 REMOVED DAMAGE AREA IAW SRM 53-00-53-2R-5.4.B. LOCATED, DRILLED & C'SUNK SIDEPLATE IAW ASA SRM 53-00-53-2R-5.4.F ALODINED REPAIR PARTS IAW SRM 53-00-53-2R-2.4.I PRIMERED REPAIR PARTS IAW SRM 53-00-53-2R-5.4.I ALODINED REPAIR PARTS IAW SRM 53-00-53-2R-5.4.I INSTALLED NUT PLATES PER IAW SRM 53-00-53-2R-5.4.K INSTALLED AFT CARGO SIDE PLATE PER SRM 53-00-53-2R-5.4.L