What was found
AFT PIT, LH TRANSITION PANEL IS CORRODED AT STA 758-808. GROUNDED - YES. EVALUATED AFT CARGO L/H TRANSITION PANEL FROM FR STA 758 TO FR STA 808. ORIGINAL MATERIAL THKS .040 PER BAC PROFILE DWG 1496-377 REMOVED .040, REMAINING .000 FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2 REMOVED DAMAGE AREA IAW SRM 53-00-53-2R-5.4.B MATERIAL ID AS BAC 1496-377 PO# 1052179.1 PER SRM 53-00-53-2R-5.4.D TABLE 201. LOCATED, DRILLED & C'SUNK & DEBURRED SRM 53-00-53-2R-5.4.F ALODINED REPAIR PARTS IAW SRM 53-00-53-2R-2.4.I PRIMERED REPAIR PARTS IAW SRM 53-00-53-2R-5.4.I PRIMERED REPAIR PARTS IAW SRM 53-00-53-2R-5.4.I INSTALLED NUT PLATES PER SRM 53-00-53-2R-5.4.K INSTALLED AFT CARGO L/H SIDE PLATE IAW SRM 53-00-53-2R-5.4.L