What was found
FWD PIT, RH AFT BULKHEAD ANGLE HAS CORROSION ON BOTTOM SIDE. GROUNDED - YES. EVALUATED FWD PIT R/H AFT BULKHEAD ANGLE; MINIMUM THICKNESS: .056, REMOVED: .026, REMAINING .045 & IS FOUND TO BE OUT OF LIMITS IAW B737-800 SRM 53-30-01. REMOVED, LOCATED & DRILLED, AND INSTALLED NEW BULKHEAD ANGLE IAW B737-800 SRM 51-40-02 & B737-800 SRM 51-40-05.