What was found
MAIN CABIN FLOOR INTERCOSTAL STA 947-967 LBL 50 HAS CORROSION AROUND ANCHOR PLATE. GROUNDED - YES. REMOVED CORROSION ORIGINAL THICKNESS .200" REMAINING THICKNESS .165" REMOVED .035" OUT OF LIMITS IAW B737-800 SRM 53-70-51-1A-1. RECEIVED, LOCATED AND DRILLED TO FIT NEW INTERCOSTAL IAW B737-800 SRM 51-40-05 AND BAC DWG # 147A5650 REV A. INSTALLED (2) NUTPLATES AND (4) CLICKBONDS IAW B737-800 SRM 51-40-10-2R FINAL INSTALL WILL BE COMPLETED IN N/R 39943 CUST CARD # G1793443. COPIE IN BACK PAGE G1793443. INSTERCOSTAL PART # :147A5660Y21. PO # 0. TOOL USED T8363L DUE DATE 03/21/2024.