Service difficulty report · Modulating Valve · Boeing 737890

Difficulty date
June 1, 2023
Submitted
June 5, 2023
Operation
Air carrier
Aircraft
N513AS
Make and model
Boeing 737890
Aircraft serial
35192
Aircraft time
51,909 hours, 15,585 cycles
Part
Modulating Valve
Part number
3989083
Part serial
10459
Condition
Faulty
Location
Rh Ecs Bay
Part time
45,556 hours, 16,614 cycles
Stage of operation
TX
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER ENGINE START, ON MASTER CAUTION RECALL RIGHT PACK LIGHT ILLUMINATED, EXTINGUISHES ON RESET. GROUNDED - YES. REMOVED AND REPLACED RH PACK TEMP CONTROL VALVE REF B737-800 AMM 21-51-10-000/400-801. PERFORMED BITE OF #1 & #2 PACK ZONE TEMP CONTROLLERS, NO FAULTS. L/H & R/H PACK OPS NORMAL, NO R/H PACK LIGHT ILLUMINATED. NO FAULTS FOUND.