What was found
FWD CARGO R/H TRANSITION CORRODED BETWEEN STA 500J+8 TO STA 520. GROUNDED - YES. REMOVED AND REPLACED TRANSITION PANEL FROM STA 500J+8 TO STA 520 IAW B737-900 SRM 51-40-02-0G-0.W= .05 O= 0.040 R= 0.024 L= 1.00 D= 0.16.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FWD CARGO R/H TRANSITION CORRODED BETWEEN STA 500J+8 TO STA 520. GROUNDED - YES. REMOVED AND REPLACED TRANSITION PANEL FROM STA 500J+8 TO STA 520 IAW B737-900 SRM 51-40-02-0G-0.W= .05 O= 0.040 R= 0.024 L= 1.00 D= 0.16.