What was found
FA'S REPORT SMOKE / FUMES IN AFT GALLEY. GROUNDED - YES. PERFORMED CABIN ODER TROUBLE SHOOTING PER FIM 05-51 TASK 814 CONFIRMED ODER COMING FROM AIR CONDITIONING SYSTREM WITH #2 ENGINE SUPPLYING PNEUMATIC POWER . STRONG ODER AND BURNS EYES IN AFT GALLEY FROM GASPERS, PERFORMED FIM 21-00 TASK 801 SMOKE OR FUMES REPORT DURING FLIGHT IN THE PASSENGER CABIN, REPLACED AIR RECIRC FILTER FOR PRECAUTIONARY MEASURE, PERFORMED INTERNAL INSPECTION OF OIL REF AMM 79-00-00-200-803-F00, PERFORMED CHECK OF THE HPC 1&2 BOROSCOPE PER AMM 72-00-00-200-804-F00, NO OIL ON BLADE FOUND AT THIS TIME, PERFORMED OIL CONTAMINATION REMOVAL FROM AIR CONDITIONING AND PNEUMATIC SYSTEM REF AMM 21-00-01-100-801 NO SMOKE OR FUMES SMELLED.