As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
REMOVED ENGINE DRIVEN HYD PUMP FOR SEAL LEAK PER TSR714593. FOUND HYD PUMP SHAFT SEAL LEAKING. GROUNDED - YES. REMOVED AND INSTALLED #1 ENG EDP MAGNETIC SEAL REF 72-60-00 AMM. REPLACED #1 ENG EDP REF AMM 29-11-11. PERFORMED EDP INSTALL TEST NO DEFECTS NOTED. NO LEAKS FOUND. THIS ACTION CLOSES TSR714593.