What was found
MAIN CABIN R1 DOOR CORNER; FWD GIRT BAR PLATE AREA HAS CORROSION ON SKIN AND (4EA) HILOSCK PINS (MARKED IN RED) GROUNDED - YES. REMOVED DAMAGE ON SILL BETWEEN FR16 AND FR17 AT -Y1952 LOWEST MATERIAL LOSS .134, HFEC AND OPEN HOLE AND DVI NO DEFECTS NOTED. FABRICATED REPAIR WASHERS, TREATED AREA AND WASHERS, INSTALLED REPAIR WASHERS AND RESTORED COATINGS REF ASA EA A320-53EA-01889 REV 00. THIS IS A CAT B REPAIR FATIGUE PROGRAM THRESHOLD 97,320 FC (FH NOT RELEVANT) INTERVAL AND METHOD TBD CORROSION INSPECTION TH 3YRS INTERVAL 3YEARS METHOD DVI PER NTM 51-90-00 DO CHECK THERE IS NO CORROSION DAMAGE CPC TO BE RESTARTED AFTER EACH INSPECTION