What was found
#2 ENG FIRE TEST INTERMITTANT. GROUNDED - YES. (RESOLVED ON W/O: 1960510 TASKCARD: N/R-00001 ) ENGINE FIRE DETECTION - OPERATIONAL TEST PASS REF AMM 26-11-00-710-801.ENGINE FIRE DETECTION LOOP RESISTANCE - SYSTEM TEST PASS REF AMM 26-11-00-730-801.ACCOMPLISHED GVI OF #2 ENG FIRE LOOPS AND HARNESSES, NO DEFECTS NOTED.REF FIM 26-10 TASK 801, FIRE DETECTION CONTROL UNIT SHOWS NO FAULTS. NO RECIENT HISTORY, GROUND VERIFICATION OK.A/C RELEASED FROM MEL 26-2B, C/N 12058559 REMOVED, SWITCH SELECTED TO NORMAL. SEAMC MITCH CONTACTED.