Service difficulty report · Control Valve · Boeing 737890

Difficulty date
July 18, 2023
Submitted
July 20, 2023
Operation
Air carrier
Aircraft
N506AS
Make and model
Boeing 737890
Aircraft serial
35690
Aircraft time
54,171 hours, 16,402 cycles
Part
Control Valve
Part number
3989085
Part serial
22282
Condition
Faulty
Location
Rh Pack
Part time
21,363 hours, 7,817 cycles
Stage of operation
IN
How discovered
V
Nature of condition
J
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WITH APU AIR AND PACKS ON, R/H PACK LIGHT ILLUMINATED WILL NOT RESET. GROUNDED - YES. PERFORMED PACK/ZONE TEMPERATURE CONTROLLER #2 BITE PROCEDURE FOUND FAULT "THIS PACK TCV" ILLUMINATED AS PER FIM 21-62 TASK 801 PERFORMED MAINTENANCE PROCEDURE FOR MEL 21-33E NO CHANGE, REQUIRES FURTHER TROUBLESHOOTING. TOMAS ICEDO 60047 07/18/2023.DUE TO SPURIOUS RESULTS WHILE TROUBLESHOOTING, R & RD ZONE TEMP CONT #2 PER 21-61-20 AND R/H TCV PER 21-51-10. C/B'S PULLED/TAGGED & UNTAGGED/RESET (4). ALL OPS CKS NML, GND VERIFICATION SUCCESSFUL, SEAMC JARRED NOTIFIED.