What was found
EMERGENCY EXIT SIGN LIGHT OUT CENTER AISLE. GROUNDED - YES. REPLACED CENTER AISLE EMERGENCY EXIT LIGHT ASSY PER AMM 33-51-01. OPS CHK FAILED BLONG 07/19/2023 REMOVED AND REPLACED POWER SUPPLY M1695 REF AMM 33-51-06-960-806. 1 C/B OPENED, TAGGED, AND RESET. ALL OP TESTS PASS. CENTER AISLE EMERGENCY EXIT SIGN ASSY L1070 OP TEST PASS.