What was found
ENG. # 2 FUEL VALVE REMAINS BRIGHT WITH ENG STRT LEVER CLOSED. GROUNDED - YES. (RESOLVED ON W/O: 1962817 TASKCARD: N/R-00002 ) ACCOMPLISHED ALTERNATE DEACTIVATION PROCEDURE ON #2 ENG REF ASA MNT CHAPTER 5 TABLE 3 ITEM 3,4 AND 7.OPENED FAN COWLS REF AMM 71-11-02/201. REMOVED AND REPLACED HPSOV SWITCH REF AMM73-21-09/201. CLOSED FAN COWLS REF AMM 71-11-02/201.REVERSED ALTERNATE DEACTIVATION PROCEDURE. REVERSED MEL MAINTAINANCE PROCEDURE. ENG #2 FUEL VALVE OPRATES NORMAL. PLACARDS REMOVED THIS CLEARS MEL73-10, C/N 24095513.HUMS QUALIFIED. SEAMC MITCH NOTIFIED.