What was found
RIGHT PACK LIGHT ILLUMINATED AT FL350, COMPLIED WITH QRH PROCEDURE. EXTINGUISHED ON TRIP RESET INITIALLY BUT CAME BACK ON . COMPLETED QRH STEPS TO INCLUDE CLOSING THE ISOLATION VALVE-WITH RIGHT PACK SHUT DOWN THE RAM DOOR REMAINED FULL OPEN. GROUNDED - YES. (RESOLVED ON W/O: 1962746 TASKCARD: N/R-00002 ) REVERSED MEL 21-5D MX PROC. BOTH INLET/EXHUAST SRADA ACTUATORS RETUREND TO NORMAL CONFIG ALL HARDWARE RETURNED TO FLY-AWAY KIT. ACCOMPLISHED PFTC BITE, NO ACTIVE FAULTS. OBSERVED RH INLET ACT. BINDING DURING BITE CHECK. REPLACED R/H SRADA INLET ACTUATOR REF AMM 21-51-21. 19 CBS PULLED/RESET. OP CHK / RIG CHK GOOD. ETOPS GROUND VERIFICATION SUCCESSFUL. THIS CLEARS MEL 21-5D C/N 25089495. PLACARDS REMOVED. SEAMC JOE NOTIFIED.