What was found
FOUND EXISTING RH WING FUEL PANEL 640KB OPENING FASTENER HOLES 4 EACH ELONGATED GROUNDED - YES. REAMED HOLES TRUE AND ROUND, FINAL HOLE SIZES #603= .343, #624= .421, #622= .4375, #615 = .4375, HFEC AND OPEN HOLE AND DVI NO DEFECTS NOTED, COLD WORKED HOLES, FABRICATED AND INSTALLED REPAIR BUSHINGS, RESTORED COATINGS REF ASA EA A320-57EA-01909 REV 00 THIS IS A CAT B REPAIR POST REPAIR INSPECTION THRESHOLD 30800 FC 58000 FH WHICHEVER OCCERS FIRST INTERVAL 3300FC 6600FH WHICHEVER OCCURS FIRST METHOD GVI WITH FUEL PANEL (DOOR) IN PLACE