What was found
FOUND EXISTING RH WING FUEL PANEL 640LB OPENING FASTENER HOLES 3 EACH ELONGATED GROUNDED - YES. REAMED HOLES TRUE AND ROUND, FINAL HOLE SIZES #603 = 0.537-IN, #655= 0.634-IN, #645= 0.325 IN HFEC ON OPEN HOLE AND DVI NO DEFECTS NOTED. COLD WORKED HOLES, FABRICATED, AND INSTALLED REPAIR BUSHINGS, AND RESTORED COATINGS REF ASA EA A320-57EA-01909 REV OO THIS IS A CAT B REPAIR, POST REPAIR INSPECTION THRESHOLD 3300 FC 6600 FH WHICHEVER OCCURS FIRST, INTERVAL 3300 FC 6600 F/H WHICHEVER OCCURS FIRST METHOD GVI WITH FUEL DOOR IN PLACE.