What was found
GE CNR 20230730051 ENG 1 S/N 60A529 IS GENERATING ALERTS FOR PS3 OUT OF RANGE, PS3 DISAGREE FAULTS OR P3B PRESSURE DISAGREE FAULTS . ICE/WATER BLOCAGE IS SUSPECT AND PSS BLOWOUT REQUIRED. (#PRI1/ETOPS). GROUNDED - YES. (RESOLVED ON W/O: 1963326 TASKCARD: N/R-00002 ) CW T/C TSR. T/C 73-ASA-01 COMPLETE. ENG 1 FAULT HISTORY: MSG 77-09002 ENG 1 EEC CH B HAS INTERNAL FAULTMSG 73-43302 COMPRESSOR DISCHARGE PRESSURE (PS3) SENSOR IS OUT OF RANGEMSG 78-44341 TR LEFT SLEEVE POSITION SENSOR SIGNAL IS OUT OF RANGEMSG 78-44461 TR RIGHT SLEEVE POSITION SENSOR SIGNAL IS OUT OF RANGEAMM TEST NO. 35 AND 36 COMPLETE.SEAMC MITCH NOTIFIED.