What was found
FWD WET AREA FR16-FR20 CORROSION ON TOP SURFACE OF CENTER LEFT AXIS Y254 LONGITUDINAL BEAM GROUNDED - YES. REMOVED CORROSION FROM LONGITUDINAL BEAM (TRACK) BETWEEN FR16-FR20, CENTER LEFT AXIS Y254, ORIGINAL THICKNESS 0.071", REMOVED 0.029", REMAINING MATERIAL 0.042" BLEND AREA. 2.0"W AND 18.0"L. FOUND TO BE OUT OF LIMITS REF A320 SRM 53-11-14-283-007: REMOVED AND REPLACED LONGITUDINAL BEAM (TRACK) P/N D5311281820401 PO: 1068071.1 REF AIRBUS DWG D53112816 REV G AND A320 SRM 51-42-11