What was found
RIGHT PACK LIGHT ILLUMINATES ON RECALL, EXTINGUISHES WHEN RESET. GROUNDED - YES. INITIAL EVAL, RH PACK LT ILLUMINATED ON P5 OVERHEAD WITH MASTER RECALL. PERFORMED PZTC BITE IAW FIM 21-62 TASK 801. LH PZTC, NO FAULTS. RH PZTC HAD TCV ON BIT, CLEARED GREEN ON VERIFY. PER FIM 21-62 TASK 831, NO FURTHER ACTION NECESSARY. RE RAN BITE, SAME RESULT. NO A/C HISTORY FOR RH PACK LT OR TCV. THIS CLEARS MEL 21-32B. SEAMC PETER NOTIFIED. PLACARDS REMOVED. NO A/C CONFIG CHANGES.