What was found
AFT WET AREA LH SIDE STR 29 AT FR65 TO FR69 HAS CORROSION GROUNDED - YES. NO LIMITS FOUND FOR AREA. LOCATED DRILLED AND DEBURRED MATERIAL DAN 50808 PO. 1069688.1 IAW A320 SRM 51-44-11 AND AIRBUS DWG D53480052. ALODINED AND PRIMED IAW A320 SRM 51-21-11. TOPCOATED IAW A320 SRM 51-23-11. REMOVED AND REPLACED 2EA SECTOPMS FROM FR64-FR70 IAW A320 SRM 51-42-11 AND AIRBUS DWG # D53480052. REMOVED AND INSTALLED 2EA SPLICES AND 1EA STRINGER CLIP IAW A320 SRM 51-42-11 AND AIRBUS DWG # D53480052.