What was found
AFT WET AREA LH SIDE STR 28 AT FR65 TO FR69 HAS CORROSION GROUNDED - YES. NO LIMITS FOR AREA. LOCATED, DRILLED AND DEBURRED STRINGER MATERIAL DA50BC8 P.O. 1069950.1 IAW A320 SRM 53-41-13. LOCATED, DRILLED AND DEBURRED MATERIAL 2024-T351 P.O. 1070120.1 IAW A320 SRM 51-44-11. MECHANICAL MATERIAL IAW A320 DWG #D53480046. ALODINED AND PRIMED STRINGER SECTIONS ANDSPLICE IAW A320 SRM 51-21-01. TOPCOAT APPLIED IAW A320 SRM53-41-13. REMOVED AND REPLACED STRINGER SECTIONS AND SPLICE IAW A320 SRM 51-42-11 AND AIRBUS DWG #D53480505. REMOVAL AND INSTALLED FWD SPLICE AND 2EA STRINJER CLIPS IAW A320 SRM 51-42-11 AND AIRBUS DWG #D53480505.