What was found
AFT WET AREA LH SIDE STR 27 AT FR65 TO FR69 HAS CORROSION GROUNDED - YES. NO LIMITS FOR STRINGER REMMOVED STRINGER 27, FR-64 TO FR-69 AND SPLICES IAW IAW A320 SRM 51-42-11. ANNEALED MATERIAL DAN 50808 P.O. 1069688.1 IAW A320 SRM 51-25-00. FORMED SECTIONS IAW A320 SRM 51-22-11. HEAT TREAT IAW A320 SRM 51-25-00. LOCATED DRILLED AND DEBURRED SECTIONS IAW A320 SRM 51-44-11.ALODINED AND PRIMED IAW A320 SRM 51-21-11. TOPCOAT APPLIED IAW A320 SRM 51-23-11. INSTALLED SECTIONS AND SPLICE IAW A320 SRM 51-42-11 AND A320 SRM 53-41-13.