What was found
AFTER LANDING LEFT FMC FAILED AND RECOVERED MULTIPLE TIMES. GROUNDED - YES. PERFORMED FMC BITE PROCEDURE FOUND FAULT FMC-L PGM FAULT AS PER FIM 34-61 TASK 801, PERFORMED FIM FMC HARDWARE/SOFTWARE FAULTS-FAULT ISOLATION, OPENED C/B A6 AT P18-2 (FMCS CMPTR-1) AND THEN CLOSED (WAITED 10 SECONDS) AFTER SYSTEM RESET VERIFIED FMC PROMPT IS SHOWN ON THE MENU, THEN THERE WAS AN INTERMITTENT FAULT AS PER FIM 34-61 TASK 807.