What was found
FO REPORTS FAN BLADE DAMAGE ON #1 ENGINE BLADE 12 & 23. GROUNDED - YES. PERFORMED FAN BLADE REPAIR ON BLADES 12 & 23 IAW AMM 72-21-02-300-801-F00. PERFORMED FLOURESCENT PENETRANT OR EDDY CURRENT INSPECTION WITHIN 10 CYCLE OR 25 FLIGHT HOURS PER SUBTASK 72-21-02-110-003-F00 AFTER REPAIR. SEAMC ARNIE NOTIFIED. C/N 10046559. (RESOLVED ON W/O: 1968767 TASKCARD: N/R-00002 ) PERFORMED FLURESCENT PENETRENT INSPECTION OF BLADE 12 & 23 PER AMM 70-40-01-901-801-F00. NO DEFECTS NOTED SEAMC MITCH NOTIFIED.