What was found
FOUND ENG 2 EEC C1 WHILE PERFORMING T/C 05-020-01. HAD CORRELATED MSG 73-43814, COMPRESSOR DISCHARGE TEMP (T3) SENOR CHANNEL - A AND CHANNEL - B SIGNALS DO NOT AGREE. GROUNDED - YES. PERFOMED IFIM TASK G73-20-00-810-856. MSG 73-43814 SHOWED NOT ACTIVE, BUT CHANGED TO ACTIVE WHILE PERFORMING ENG IDLE TEST. LATCH MSG RETURNED WITH MSG 73-43814. MSG 36-10171 IASC-R (BLEED) HAS NO ENGINE - 2 PS3 AND T3 DATA ON MDS-DPC GP 2 BUS ALSO POPULATED. D GREEN 22683 09/13/2023 MSG 73-43814 PREVIOUSLY DEFFERED ON LOG PAGE 60647662. PERFORMED IFIM TASK 36-10-00-810-810 FOR MSG 36-10171, #2 ELECTRICAL LRU REPLACEMENT TEST PASSED. FAULT NOT ACTIVE INTERMITTENT FAULT.